FLEXEON LC-1500 Reverse Osmosis System

 

LC-Series Reverse Osmosis Systems

FLEXEON LC-Series Reverse  Osmosis Systems are manufactured for light commercial applications and feature a compact space-saving design. The versatile design allows for either wall-mounted or free-standing operation. The LC-Series Systems comes pre-assembled, and ready for immediate on-line service with minimal set up and simple utility connections.

FLEXEON LC-Series Reverse Osmosis Systems  have been engineered for capacities ranging from 750 to 1,500 gallons per day, and feature a Fluid-O-Tech Low Lead Brass Rotary Vane pump designed for enhanced performance.

Standard Features

  • White Powder Coated Steel Bracket
  • 10 Micron Carbon Block Pre-Filter ( on LC-750)
  • AXEON by Pentek Housings
  • Fluid-O-Tech Low Lead Brass Rotary Vane High Pressure Pump
  • ODP High Efficiency Carbonator Motor
  • AXEON HF5-Series Ultra Low Energy Membranes
  • Permeate Flow Meter
  • Concentrate Flow Meter
  • Concentrate Recycle Flow Meter
  • Feed Solenoid Valve
  • 316 Stainless Steel Concentrate and Recycle Valves
  • 0- 300 psi Pump Pressure Gauge
  • 0- 100 psi Post-Filter Pressure Gauge
  • 0- 100 psi Permeate Pressure Gauge
  • John Guest Push/Pull Fittings with Locking Safety Clips
  • Low Pressure Switch for Pump Protection
  • Permeate High Pressure Switch
  • HM Digital DM-2 TDS Meter
  • 20’’

Options and Upgrades

  • Storage Tanks
  • Fluid-O-Tech Stainless Steel Rotary Vane Pump
  • Blending Valve

Product Specifications

DESIGN                               LC-1500
Configuration  Single Pass
Feed Water Source (ppm) TDS up to 1,000
Standard Recovery   Up to 75%
                                                   Rejection and Flow Rates
Nominal Salt Rejection  98.5%
Permeate Flow Rate 1.04 gpm
Concentrate Flow Rate ( min.) 1.7 gpm ( 6.4) lpm)
Concentrate Recycle Flow Rate 1.4 gpm (5.2 lpm)
                                                           Connections
Feed (in) 3/8 QC
Permeate (in) 3/8 QC
Concentrate (in) 3/8 QC
                                                           Membranes
Membrane Per Vessel 1
Membrane Quantity 2
Membrane Size 3018
                                                             Vessels
Vessel Array 1 ( Series)
Vessel Quantity   2
                                                              Pumps
Pump Type Rotary Vane 1001 Low Lead Brass
Motor ( HP) 3/4 HP
RPM@ 60 HZ 1725
                                                            Electrical
Standard Voltage 110 V, 1PH ,60 HZ
                                                  System Dimensions
*Approx. Dimensions L X W X H (in/cm) 17 x 7.5 x 29 (43.18 x 19.05 x 73.66)
*Approx. Weight (lb/kg) 60(27.22)
*Product flow and recovery rates are based on feed conditions of 1000 ppm TDS at 77◦.Treatment ability of the RO System is dependent on feed water quality. Higher TDS and/or lower temperatures will reduce product flow. Performance projections should be run for each installation.
                                                                                                                                              Operating Limits  
Design Temperature 77◦F Max. Turbidity NTU 1
Max. Feed Temperature 85◦F Max. Free Chlorine ppm 0
Min. Feed Temperature 40◦F Max. TDS ppm Up to 1,000
Max. Ambient Temperature 120◦F Max. Hardness GPG 1
Min. Ambient Temperature 40◦F Max. pH (Continuous) 11
Max. Feed Pressure (psi) 85 Min. pH (continuous) 5
Min. Feed Pressure (psi) 45 Max.pH (Cleaning 30 min.) 12
Max. Operating Pressure (psi) 90 Min. pH (Cleaning 30 Min.) 2
Max. SDI Rating (SDI) <3
 
 
Test Parameters: Static pressure tested.
                             * Appropriate Pre-filtration must be installed in order to prevent premature membrane fouling.