FLEXEON AT-1000P REVERSE OSMOSIS SYSTEM

Home / Shop

FLEXEON AT-1000P REVERSE OSMOSIS SYSTEM

$4,895.00
FLEXEON  AT-1000P REVERSE OSMOSIS SYSTEM
FLEXEON  AT-1000P REVERSE OSMOSIS SYSTEM

Home / Shop

FLEXEON AT-1000P REVERSE OSMOSIS SYSTEM

$4,895.00
Model Number: FLEXEON AT-1000P REVERSE OSMOSIS SYSTEM
Maximum quantity exceeded
Minimum purchase amount of 0 is required
Maximum purchase amount of 0 is allowed
4895.000
Manufacturer:
Facebook
X
Email
Pinterest
Google+
LinkedIn
Digg
  • Description

FLEXEON AT-1000P REVERSE OSMOSIS SYSTEM

  FLEXEON AT-Series Reverse Osmosis (RO) Systems are designed and manufactured for commercial and light industrial applications. These systems have been engineered for capacities ranging from 500 - 1,000 gallons per day and for municipal and well water supplies. FLEXEON AT-Series RO Systems come pre-assembled, fully tested, preserved and sanitized and only require simple utility connections once on site. Systems come ready for immediate on-line service, minimal set up and with little adjustment required. FLEXEON AT-Series Reverse Osmosis Systems are designed for overall high performance, high recovery rates, minimal energy consumption and offer great savings with low maintenance and operation costs. These systems feature a space saving expandable design, exceptional pre-filtration, quality components and allow for many options and upgrades to suit most applications.   Benefits ■ Fully Equipped and Customizable ■ Expandable and Lightweight Design ■ Compact Space Saving Design ■ Components Easily Accessible Benefits AT-Series Reverse Osmosis Systems ■ Pre-Plumbed, Wired and Assembled ■ Factory Tested and Preserved ■ Low Operation Costs ■ Low Maintenance Costs ■ Easy Maintenance and Servicing ■ CE Compliant ■ 1-Year Limited Warranty ■ Made in the U.S.A.   Models  AT-1000P                                                                           PREMIER (P) Frame White Powder Coated Aluminum Frame                                       ✓ Controls Manual On and Off Control Switch Minitrol Computer Controller Minitrol IF Computer Controller                                                                ✓ Pre-Treatment Lockout                                                                             ✓ Tank Level Input                                                                                       ✓ LED Controller Display                                                                             ✓ Feed Solenoid Valve                                                                                 ✓ Concentrate Recycle Valve                                                                       ✓ Feed Low Pressure Switch 15-30 psi                                                        ✓   Instrumentation AXEON® Permeate Flow Meter                                                                ✓ AXEON® Concentrate Flow Meter                                                            ✓ Concentrate Recycle Flow Meter                                                              ✓ AXEON® 316 Stainless Steel Concentrate Valve                                      ✓ AXEON® 0-100 psi Pre-Filter In Pressure Gauge                                     ✓ AXEON® 0-100 psi Pre-Filter Out Pressure Gauge                                  ✓ AXEON® 0-300 psi Pump Pressure Gauge                                               ✓ HM Digital™ PS-100 Permeate TDS Controller HM Digital™ PS-202 Dual Permeate and Feed TDS Controller                 ✓   Features Feed Flush AXEON® 5 Micron Sediment Pre-Filter                                                      ✓ AXEON® 10 Micron Carbon Block Pre-Filter                                              ✓ AXEON® by Pentek® Single O-Ring Filter Housings                                  ✓ AXEON® HF1 Low Energy RO Membranes AXEON® HF4 Extra Low Energy RO Membranes                                      ✓ AXEON® PVC Membrane Housings                                                           ✓ Fluid-O-Tech™ Brass Rotary Vane High Pressure Pump Fluid-O-Tech™ Stainless Steel Rotary Vane Pump                                     ✓ ODP High Efficiency Carbonator Motor                                                       ✓ Note: All 50Hz systems come standard with AXEON HF4 Extra Low Energy RO Membranes.  

Specifications

Design Configuration                                                                 Single Pass Feed Water Source ***                                                   TDS <2000 ppm Standard Recovery Rate†                                             41% Recovery with Concentrate Recycle                               Up to 75%   Rejection and Flow Rates Nominal Salt Rejection %                                                98.5 Permeate Flow* gpm (lpm)                                            0.69 (2.61) Minimum Feed Flow gpm (lpm)                                     1.69 (6.40) Maximum Feed Flow gpm (lpm)                                     4.00 (15.14) Minimum Concentrate Flow gpm (lpm)                           1.00 (3.78)   Connections Feed inch                                                                         1 FNPT Permeate inch                                                                  3/8 Tube Concentrate inch                                                              3/8 Tube Membranes Membrane(s) Per Vessel                                                   1 Membrane Quantity                                                            3 Membrane Size                                                                  2521   Vessels Vessel Array                                                                       1:1:1 Vessel Quantity                                                                   3 Pumps Pump Type                                                                        Rotary Vane 601 Brass or 611 SS Motor HP                                                                           1/2 RPM @ 60 (50 Hz)                                                           1725 (1465)   Electrical Standard Voltage                                                               110V, 60Hz, 1 PH, 8.2A Voltage Options                                                                  220V, 60Hz, 1 PH, 3.9A 220V, 50Hz, 1 PH, 4.1A   Systems Dimensions ** L x W x H inch (cm)                                                            14 x 20 x 27 (36 x 51 x 69) Weight lb. (kg)                                                                    70 (31.75) * Product Flow rates and recovery are based on equipment test parameters. ** Does not include operating space requirements. *** Treatment ability of the RO system is dependent on feed water quality. Performance projections must be run for each installation.   Operating Limits Maximum Feed Temperature °F (°C)                                     85 (29.00) Maximum Free Chlorine ppm                                                 0 Minimum Feed Temperature °F (°C)                                      40 (4.44) Maximum TDS ppm                                                               <2000 Maximum Ambient Temperature °F (°C)                                120 (48.89) Maximum Hardness gpg††                                                     0 Minimum Ambient Temperature °F (°C)                                 40 (4.44) Maximum pH (Continuous)                                                     11 Maximum Feed Pressure psi (bar)                                         85 (5.86) Minimum pH (Continuous)                                                      5 Minimum Feed Pressure psi (bar)                                          45 (3.10) Maximum pH (Cleaning 30 Min.)                                            12 Maximum Operating Pressure psi (bar)                                 150 (10.34) Minimum pH (Cleaning 30 Min.)                                             2 Maximum SDI Rating SDI                                                      <3 Maximum Turbidity NTU                                                         1   Test Parameters: 550 TDS Filtered (5 Micron), De-Chlorinated, Municipal Feed Water, 65 psi (4.50 bar) Feed Pressure, 150 psi (10.34 bar) Operating Pressure, 77 Degrees F (25 Degrees C), Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation. † Low temperatures and high feed water TDS levels will significantly affect systems production capabilities. Computer projections should be run for individual applications. †† Scale prevention measures must be taken to prolong membrane life.